Room Design & Layout

Insulated envelope · trolley grid · U-flow air path

Envelope specification

ParameterValueNotes
Internal dimensions8.0 × 4.0 × 2.20 m (L × W × H) Single bay; ~32.0 m² floor area
Wall / roof panels50 mm PUF sandwich, white food-grade steel facing λ = 0.022 W/m·K → U ≈ 0.44 W/m²·K
Floor100 mm reinforced concrete, polyurethane-topped, coved to walls Vapour barrier below slab; thermal break at panel base
Door1.0 × 2.0 m insulated, gasketed, outward-opening Interlocked with fan & HP for safety
Vapour barrierContinuous, sealed at all panel joints and floor junctions Critical — moist 62°C air will condense on any cold bridge
Structure loss (design)1.7 kWΔT = 32 K vs 30°C ambient

Trolley layout & air path

16 trolleys arranged in 2 channels of 2 abreast × 4 along the length. Air enters through a supply fan wall at the heat-pump end, travels through the supply channel (4 trolley passes in series), makes a single U-turn at the door end, and returns through the second channel (4 more passes) to the heat-pump intake. 8 total passes · 410 Pa pressure drop · identical air path for every trolley.

S1 — Plan view: 16 trolleys, U-flow arrows, partition-free wide channels.
S1 — Plan view: 16 trolleys, U-flow arrows, partition-free wide channels.
S2 — Longitudinal section A-A through the supply channel.
S2 — Longitudinal section A-A through the supply channel.
3D cutaway: trolleys, fan wall, U-turn plenum, HP unit.
3D cutaway: trolleys, fan wall, U-turn plenum, HP unit.

Cross-section and elevations

S3 — Cross-section B-B showing both channels and abreast trolleys.
S3 — Cross-section B-B showing both channels and abreast trolleys.
S4 — Door-end and heat-pump-end elevations.
S4 — Door-end and heat-pump-end elevations.
← 2 · ProcessPage 3 of 124 · Trolley →